![]() ![]() Replace the electrical cover on the unitĪlways call an experienced HVAC professional to check your capacitor.Replace the wires exactly as they were taken off in step 9 using your notes.(opt2) watch the reading rise from zero (0) to its max and then fall back to zero (you are charging and discharging the capacitor on the resistance setting) if the maximum reading is in the operating specification on the side of the capacitor, then the capacitor is good.(opt2) with the meter set on ohms, check the reading with one lead on C and the other on either the HERM or FAN tabs.For a dual capacitor, typical termination markings are C, H, and F. 45/5 MDF (f) Dual Run Round Capacitor markings. In most cases, the dual capacitor has 3 terminals (figure 2) and the start/run capacitor have 2. (opt1) if the reading is in the operating range written on the side of the capacitor then the capacitor is good This kind of AC capacitor often saves more space and is easier to replace when fails.(opt1) Take the leads from the meter, with the meter set on micro-farads and check the reading with one lead on C and the other on either the HERM or FAN tabs.Brown to Fan, red to C, Purple to C, Yellow to HERM) each brand of system may vary slightly, so write down the terminal-wire connection Make a note which wire is connected to which terminal (ex.Take the screwdriver and touch both the “FAN” and the “C” common tabs on the top of the capacitor to discharge the FAN side of the capacitor.Take the screwdriver and touch both the “C” (common) connection and the “HERM” (compressor) tabs on the top of the capacitor to discharge the HERM side of the capacitor. Compositor: Mackenzie-Harris Binder (person): Jensen Bindery Publisher: Bridwell Library. ![]() Get your screwdriver with an insulated handle.Remove the panel covering the electrical components.Try turning the power on and off again to see if it was a one-time issue with the motor or a recurring problem. Any humming noises indicate a problem with the air conditioning system or the components of the AC unit. Turn thermostat to OFF (this will turn off the 24 volts to unit and the humming will stop) A sure sign of a bad AC capacitor is a humming sound from within the access panel.However, because it is a servicing job, labor is the. The total cost of having an AC capacitor installed is between 100 and 200 typically. There are some options that are as much as 200, but that is mostly unnecessary and avoidable. Check that the outdoor unit is not running (you will hear a hum but the unit is not running) Most homeowners spend between 30 and 50 on an AC capacitor, but there are options in the 10-15 range.Turn your thermostat down below room temperature and select cooling (this will still send 24 volts to the outside unit but the 240 volts required to run the compressor and fan should be off from the disconnect or circuit breaker).Remove the disconnect or turn off the circuit breaker this should turn off the 240 volts to the outside unit.If you are unfamiliar with high voltage in your outdoor unit, do not attempt this procedure!!!!!. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |